Opentrons logo
Cancel

Thermocycler Module

$9,750

The Opentrons Thermocycler Module GEN2 is a fully automated on-deck thermocycler, providing hands-free PCR in a 96-well plate format. Compatible with Opentrons hardware and software to allow for fully automated PCR reaction setup and thermocycling on your Opentrons robot. The heated lid and disposable seal fit tightly over the plate, ensuring efficient sample heating and minimal evaporation.

Closed Right 3qtr Hero TCGEN2
Closed Front TCGEN2
Closed Left 3qtr TCGEN2 with Air Duct
Closed Left 3qtr TCGEN2
Closed Left Side TCGEN2 with Air Duct
Closed Left Side TCGEN2
Closed Right 3qtr Hero TCGEN2 with Air Duct
Closed Right 3qtr Hero TCGEN2
Open Left 3qtr TCGEN2 with Air Duct
Open Left 3qtr TCGEN2
Open Right 3qtr Hero TCGEN2 with Air Duct
Open Right 3qtr Hero TCGEN2
TCGEN2 Plate Seal 1

Features

  • Programmable, on deck thermocycler for completely hands-free PCR
  • Thermal block temperature range of 4–99 °C, with lid temperature up to 110 °C
  • Programmable through Python API and Protocol Designer
TCGEN2 Plate Seal

Prevent sample loss with disposable seals

Opentrons GEN2 Thermocycler Seals are adhesive-backed Ethylene Propylene Diene Monomer (EPDM) seals designed for use with the fully-automated Opentrons GEN2 Thermocycler.

Tech Specs

Open Right 3qtr Hero TCGEN2
Dimensions (open)

244.95 mm L x 172 mm W x 310.1 mm H

Dimensions (closed)

244.95 mm L x 172 mm W x 170.35 mm H

Dimensions (closed with External Fan Duct)

315.32 L x 172 mm W x 170.35 H

Accommodates

Full-skirted 96-well, 0.2 mL PCR plates

Thermal block temperature range

4–99 °C

Thermal block maximum heating ramp rate

4.25 °C/s between ambient and 95 °C

Thermal block maximum cooling ramp rate

2.0 °C/s between 95 °C and ambient

Lid temperature range

37–110 °C

Weight

8.4 kg

Module power input

36 VDC 6.1 A

Power adapter input

120-240 VAC, 50/60 Hz, 8.5A@115VAC, 5.0A@230VAC

Recommended plates

We recommend using Opentrons Tough PCR Plates with the Opentrons Thermocycler Modules, as they are full-skirted and have a rigid polycarbonate frame with thin-walled polypropylene wells. The plate lift mechanism that releases the plate from the Thermocycler after cycling engages with the edges of full-skirted PCR plate so the plate can be easily removed. The rigid frame of the PCR plate is compatible with a gripper, prevents the plate from warping, and keeps the plate secure in the block when the lid opens.

Frequently Asked Questions

For FAQs about the OT-2 and other products, click here.

One Thermocycler Module can be used at a time on the OT-2.

The Thermocycler Module is intended for use with full-skirted, rigid, 96-well, 0.2 mL PCR plates. We recommend using Opentrons Tough PCR Plates.

Risk free 60-day demo

Try the OT-2 in your lab today and take advantage of protocols designed for sharing and editing.